Relays REL-MR-24DC/21-21/MS

REL-MR-24DC/21-21/MS

Subscribe to get prices

Model: REL-MR-24DC/21-21/MS

Order No: 2987943

SKU: 10000099054701

Condition: New Sealed Under Guarantee

Size: 25.00 mm,12.70 mm,29.00 mm

Weight: 20.00g

Product Selection Engineer:ChuFuHua

In Stock

Brief Introduction

REL-MR-24DC/21-21/MS

Product Type: Single Relay.Electrical characteristicsInput Data: Rated input voltage is 24V DC and input voltage range is 19.2V DC to 52.8V DC. The drive is monostable and non-polarized, with a typical input current of 18mA, a typical response time of 9ms, and a typical release time of 6ms at the rated input voltage.Output data: 2 changeover contacts for contact switching type, single contact type for switching contact, contact material for AgNi. The maximum switching voltage is 250V AC/DC, the minimum switching voltage is 12V (at 10mA), the limited continuous current is 8A, the maximum inrush current is 16A (20ms), and the minimum switching current is 10mA (at 12V). The switching capacitances are 1A (at 24V, DC13), 1.5A (at 24V, AC15), 1.5A (at 120V, AC15), and 1.5A (at 240V, AC15). UL 508 compliant motor loads are 1/4HP, 120V AC (normally open contact), 1/2HP, 240V AC (normally open contact), 1/4HP, 120V AC (normally closed contact), 1/3HP, 240V AC (normally closed contact).

Description

Product Type: Single Relay.

Electrical characteristics

Input Data: Rated input voltage is 24V DC and input voltage range is 19.2V DC to 52.8V DC. The drive is monostable and non-polarized, with a typical input current of 18mA, a typical response time of 9ms, and a typical release time of 6ms at the rated input voltage.

Output data: 2 changeover contacts for contact switching type, single contact type for switching contact, contact material for AgNi. The maximum switching voltage is 250V AC/DC, the minimum switching voltage is 12V (at 10mA), the limited continuous current is 8A, the maximum inrush current is 16A (20ms), and the minimum switching current is 10mA (at 12V). The switching capacitances are 1A (at 24V, DC13), 1.5A (at 24V, AC15), 1.5A (at 120V, AC15), and 1.5A (at 240V, AC15). UL 508 compliant motor loads are 1/4HP, 120V AC (normally open contact), 1/2HP, 240V AC (normally open contact), 1/4HP, 120V AC (normally closed contact), 1/3HP, 240V AC (normally closed contact).
Unsubscribe

Discount Code

Subscribe
Please check the item(s) you are interested in. (required)

Enter email to obtain information:

Subscription successful

Price list will be sent to you by email within 24hrs.

USE : 0.010680913925171